Monitor says:
Hit Number Index Box Time Energy Position
1 305 339 0.0000 42.49 197.95
My analysis says:
SINGLE BOX HIT DUMP BOX 339
ENERGY (using TDCZ) 40.37450 (using ADCZ) 39.28723
TIME 180595 104135
TRIG CUT 129 = Bari Muon, more than one uVAX present in event.
Conclusion: This is a muon or other penetrating particle since it
triggered Bari.
Monitor says:
Hit Number Index Box Time Energy Position
2 741 165 0.8417 10.05 54.41
My analysis says:
SINGLE BOX HIT DUMP BOX 165
ENERGY 12.35293 9.242111
TIME 180595 104136
ADCZ cut -307.7448 276.7705
Conclusion: Misreconstructed energy due to ADCZ vs. TDCZ mismatch
Monitor says:
Hit Number Index Box Time Energy Position
3 402 261 0.9118 10.96 -420.09
My analysis says:
SINGLE BOX HIT DUMP BOX 261
ENERGY 11.08445 12.14613
TIME 180595 104136
kept
Conclusion: Legitimate background event
Monitor says:
Hit Number Index Box Time Energy Position
4 312 371 1.1812 10.34 -347.58
5 375 479 1.5620 13.11 112.07
My analysis says:
SINGLE BOX HIT DUMP BOX 371
ENERGY (fron TDCZ) 0.3626242 (fron ADCZ) 4.031045
TIME 180595 104136
SINGLE BOX HIT DUMP BOX 479
ENERGY 0.6834558 2.906543
TIME 180595 104136
Conclusion: Calibration constants screwed up? Probably low energy noise
Monitor says:
Hit Number Index Box Time Energy Position
6 313 370 1.9679 11.19 68.02
My analysis says:
SINGLE BOX HIT DUMP BOX 370
ENERGY 11.20513 10.49737
TIME 180595 104137
kept
Conclusion: Legitimate background event
Monitor says:
Hit Number Index Box Time Energy Position
7 404 212 2.9229 12.52 -363.42
My analysis says:
SINGLE BOX HIT DUMP BOX 212
ENERGY 13.69658 11.21717
TIME 180595 104138
ADCZ cut -439.3704 7.096680
Conclusion: Misreconstructed energy due to ADCZ/TDCZ mismatch
Monitor says:
Hit Number Index Box Time Energy Position
8 405 256 3.0477 15.38 -477.82
My Analysis says:
SINGLE BOX HIT DUMP BOX 256
ENERGY 15.72914 7.339157
TIME 180595 104138
ADCZ cut -507.7136 402.3271
Conclusion: Misreconstructed energy due to ADCZ/TDCZ mismatch
Monitor says:
Hit Number Index Box Time Energy Position
9 413 240 5.9943 11.33 363.17
My analysis says:
SINGLE BOX HIT DUMP BOX 240
ENERGY 10.90847 10.69911
TIME 180595 104141
kept
Conclusion: Legitimate background event.
Monitor says:
Hit Number Index Box Time Energy Position
10 383 444 7.9229 11.01 -537.18
My analysis says:
SINGLE BOX HIT DUMP BOX 444
ENERGY 1.226297 6.019756
TIME 180595 104143
Conclusion: Bad calibration constants? Probably low energy noise.
Monitor says:
Hit Number Index Box Time Energy Position
11 323 368 8.2067 42.64 -508.83
My analysis says:
SINGLE BOX HIT DUMP BOX 368
ENERGY 42.34505 40.92985
TIME 180595 104143
kept
Conclusion: Must be a muon, based on 42 MeV energy, but near end of a
bottom tank. I could probably reject this event based on nearby streamer
tubes hit, but there was probably only one ST hit on the bottom of the box.
(I would have rejected it if there had been one on top and on bottom of the
box). A true corner clipper.
Monitor says:
Hit Number Index Box Time Energy Position
12 328 365 9.6353 11.42 427.72
My analysis says:
SINGLE BOX HIT DUMP BOX 365
ENERGY 11.37042 7.629733
TIME 180595 104144
ADCZ cut 421.0159 -288.7803
Conclusion: Misreconstructed energy based on ADCZ/TDCZ mismatch.
That's all folks... I'll look into the events that give weird energies in
my analysis. Note that they are all verticals.
Rich