13JAN99 GC test complete

Erik Katsavounidis (Erik.Katsavounidis@lngs.infn.it)
Wed, 13 Jan 1999 19:06:42 +0100

Hi all,

The advertized GC calibration for today is now complete. GC-like LED events
were generated in SM1/2, SM3/4, SM5/6 and finally on all 6 SMs. The LED
parameters (pulse height and widths) were kept the same in all tests. Below
you may find the log for each combination of SMs. Bursts limited within 2 SMs
had a total of 100+50 hits generated over 2+10 seconds. The burst over the
entire detector had 300+150 hits generated over 2+10 seconds.
At least 10 minutes of "silence" interval between SM configuration changes
was introduced. All times reported in the logs below are VSMAC3 times
which are 8min20sec behind respect to VXMACB clock.

On MACRO's main acquisition console GC alarms were received from PHRASE
only from SM1/2 and SM5/6.

At this point it will be useful to have some input from the GC working
group on what was detected from each of the systems on the above bursts
and understand if further tuning of the software is needed.

The relevant question now is how frequently we want to perform this
calibration. Given that the calibration events are pre-announced
and well separated, online monitors may be designed to flag such
bursts as calibration but still forward the alarm to the international
watch. Having this test once a month -- say the first maintenance day
of each month -- I feel will be a good starting point.

A presto,
--Erik

********************************************************************************
************************** LOG of first test in SM1/2 **************************
********************************************************************************

Operation in AUTO mode
$LED/GC calibrations on which microvax?
1
$LED/GC calibrations on which microvax?
0
$DATA file containing LED settings?
gc_calib.dat
VMS SET TLEN NEUT VOLTH VOLTV WIDTH PERIOD TDELH TDELV
DATE_TIME # (sec) # (V) (V) (nsec) (msec) (nsec) (nsec)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
Firing fakeboxes ...
13-JAN-1999 16:54:36.47 0 2.5 0 1.00 1.00 50 250.00 0 0
13-JAN-1999 16:54:39.22 End of firing fakeboxes
13-JAN-1999 16:54:39.24 Waiting 30.0 secs ...
13-JAN-1999 16:55:09.46 1 2.0 100 -4.20 2.10 80 25.00 75 1075
Boxes turned on at rate = 60.29344 Hz
Iteration rate = 38.05405 Hz
13-JAN-1999 16:55:13.11 2 10.0 50 -3.80 1.90 80 250.00 75 1075
Boxes turned on at rate = 47.95016 Hz
Iteration rate = 39.37695 Hz
13-JAN-1999 16:55:24.29 Waiting 30.0 secs ...
Firing fakeboxes ...
13-JAN-1999 16:55:54.60 3 2.5 0 -3.80 1.90 80 250.00 0 0
13-JAN-1999 16:55:57.34 End of firing fakeboxes

********************************************************************************
************************** LOG of test in SM3/4 **************************
********************************************************************************

Operation in AUTO mode
$LED/GC calibrations on which microvax?
2
$LED/GC calibrations on which microvax?
0
$DATA file containing LED settings?
gc_calib.dat
VMS SET TLEN NEUT VOLTH VOLTV WIDTH PERIOD TDELH TDELV
DATE_TIME # (sec) # (V) (V) (nsec) (msec) (nsec) (nsec)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
Firing fakeboxes ...
13-JAN-1999 17:06:40.10 0 2.5 0 1.00 1.00 50 250.00 0 0
13-JAN-1999 17:06:42.84 End of firing fakeboxes
13-JAN-1999 17:06:42.86 Waiting 30.0 secs ...
13-JAN-1999 17:07:13.08 1 2.0 100 -4.20 2.10 80 25.00 75 1075
Boxes turned on at rate = 60.14757 Hz
Iteration rate = 37.28156 Hz
13-JAN-1999 17:07:16.67 2 10.0 50 -3.80 1.90 80 250.00 75 1075
Boxes turned on at rate = 46.97156 Hz
Iteration rate = 38.49474 Hz
13-JAN-1999 17:07:28.06 Waiting 30.0 secs ...
Firing fakeboxes ...
13-JAN-1999 17:07:58.36 3 2.5 0 -3.80 1.90 80 250.00 0 0
13-JAN-1999 17:08:01.14 End of firing fakeboxes

********************************************************************************
************************** LOG of test in SM5/6 **************************
********************************************************************************

Operation in AUTO mode
$LED/GC calibrations on which microvax?
3
$LED/GC calibrations on which microvax?
0
$DATA file containing LED settings?
gc_calib.dat
VMS SET TLEN NEUT VOLTH VOLTV WIDTH PERIOD TDELH TDELV
DATE_TIME # (sec) # (V) (V) (nsec) (msec) (nsec) (nsec)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
Firing fakeboxes ...
13-JAN-1999 17:18:16.60 0 2.5 0 1.00 1.00 50 250.00 0 0
13-JAN-1999 17:18:19.35 End of firing fakeboxes
13-JAN-1999 17:18:19.37 Waiting 30.0 secs ...
13-JAN-1999 17:18:49.60 1 2.0 100 -4.20 2.10 80 25.00 75 1075
Boxes turned on at rate = 60.64466 Hz
Iteration rate = 38.77282 Hz
13-JAN-1999 17:18:53.21 2 10.0 50 -3.80 1.90 80 250.00 75 1075
Boxes turned on at rate = 47.96253 Hz
Iteration rate = 39.16940 Hz
13-JAN-1999 17:19:04.44 Waiting 30.0 secs ...
Firing fakeboxes ...
13-JAN-1999 17:19:34.77 3 2.5 0 -3.80 1.90 80 250.00 0 0
13-JAN-1999 17:19:37.50 End of firing fakeboxes

********************************************************************************
************************** LOG of full MACRO test **************************
********************************************************************************

Operation in AUTO mode
$LED/GC calibrations on which microvax?
1
$LED/GC calibrations on which microvax?
2
$LED/GC calibrations on which microvax?
3
$LED/GC calibrations on which microvax?
0
$DATA file containing LED settings?
gc_calib_123.dat
VMS SET TLEN NEUT VOLTH VOLTV WIDTH PERIOD TDELH TDELV
DATE_TIME # (sec) # (V) (V) (nsec) (msec) (nsec) (nsec)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
Firing fakeboxes ...
13-JAN-1999 17:31:52.36 0 2.5 0 1.00 1.00 50 250.00 0 0
13-JAN-1999 17:31:55.13 End of firing fakeboxes
13-JAN-1999 17:31:55.18 Waiting 30.0 secs ...
13-JAN-1999 17:32:25.84 1 2.0 300 -4.20 2.10 80 40.00 75 1075
Boxes turned on at rate = 71.38461 Hz
Iteration rate = 10.83077 Hz
13-JAN-1999 17:32:29.58 2 10.0 150 -3.80 1.90 80 400.00 75 1075
Boxes turned on at rate = 63.60310 Hz
Iteration rate = 10.81550 Hz
13-JAN-1999 17:32:40.85 Waiting 30.0 secs ...
Firing fakeboxes ...
13-JAN-1999 17:33:11.18 3 2.5 0 -3.80 1.90 80 250.00 0 0
13-JAN-1999 17:33:13.91 End of firing fakeboxes