Subject: 6T11-1 and 6T02-0
From: ORSINI MASSIMO (Massimo.Orsini@lngs.infn.it)
Date: Wed Mar 29 2000 - 07:22:12 EST
Hi guys,
today we opened 6T11-0 and we replaced the PMT and the base only on side 00.
Furthermore, we found 6T02-0 under gain (-3.5 mV) and I set the new gain for
both PMTs.
They are going to be back in acquisition in the afternoon.
A presto,
Massimo