Subject: Data shift report (27-mar-2000 to 31-mar-2000)
Roberto.Giuliani@lngs.infn.it
Date: Fri Mar 31 2000 - 13:00:46 EST
Data shift report (27-mar-2000 to 31-mar-2000)
WFD warnings:
19316 2b01-0 LED PULSE
19310 event 19 , 0 sup off
19310 2b01-0 LED PULSE event 523
19309 2b01-0 LED PULSE event 4307,4313 !29mar00
19308 SM1 CH36 event 31 0 sup off
19308 sm5ch20 ped std deviation=2.01
19307 2b01-0 LED PULSE event 7641,7643
19306 2b01-0 LED PULSE event 2413,2438
19305 2b01-0 LED PULSE event 2147,2170
19305 5507 0 sup off for (2b10-2b14)side zero, 0 sup off
19302: 0 sup off for eve 47
19302 2b01-0 LED PULSE event 8807,8822
19299 2b01-0 LED PULSE event 10615,10689
19299 sm6ch29 (6E10-1) eve 5507
19297 2b01-0 LED PULSE event 6764,6778,6815
19297 (1E01-1E07) side zero, 0 sup off
19296 2b01-0 LED PULSE eve 10685
19295 sm3 ch31 ped std deviation !NOT other warning
19293 sm2 ch32 (2t01-2707)side zero event 30 Zero sup off
19291 2b01-0 LED PULSE event 31
TRIGGER RATE :
TOHM --> 1T11 ~20mHz, 2B04 < 10mHz ,2T16 ~10mHz, 3T12 ~40mHz(!)
3T17 10~mHz, 3T06 ~10mHz, 3T12 ~40 mHz 4T02 ~10mHz,
4T10 ~10mHz, 4T11 ~10mHz,4T13 ~10mHz, 4T12 < 10 mHz
5T02 ~10mHz, 5T06 10 mHz, 6T11
ERP --> 2C15 ~2mHz, 3B07 ~9mHz, 6T08 ~8mHz
LIP --> 2E10 ~8mHz, 3E04 ~8mHz, 6T12 ~8mHz
ERP-GC --> 1W02 ~50 mHz, 1T07 50 mHz,6S04 ~120mHz, 6S07 ~60mHz
There were a lot of LAMOSSKA triggers not justified corrisponding to the
2b01-0 LED PULSE.
CSPAM/ERP efficiency:
According to Chuck Lane Plots we have 3B07 45%, 3B10 ~80%.
The most interesting is 5T01 @80% just for CSPAM56/SM5
(5T01 for CSPAM45 is @100%)
ERP/LIP efficiency:
1B16, 1C15, 1W11 looks like dead.
SPU: still hits on ERPI, ERPII, SPARE and LED on uVax1.
STOP MASTER:
The stop master of sm2 is working without problem.
We suspect that it will originate some problems from
the Circuit that drives the output for this module.
CALIBRATIONS:
Full set of calibrations on uVax1.
VARIOUS:
Today the DDNOW was stalled @ run 19316 but now is working fine.
MACRO HARDWARE:
We have sent 5 power supply to Elexind.
Onother power supply has a broken transformer so we decided not to
send it to repair.
I have tested 6 phototube and 4 of them were BAD and 2 nead to be
tested again.
Ciao, Roberto Giuliani