Subject: Stop Master fake hits on SM3
Roberto.Giuliani@lngs.infn.it
Date: Fri Feb 25 2000 - 05:15:35 EST
Giuliani, 25-FEB-2000
Hi All,
On 23-FEB-2000, (Calibration day) we worked on SM3, so it is possible
that we affected the STOP MASTER on SM3.
The first MACRO RUN with full config was 19149, during this run occourred
312 fake hits on SM3 STPM (SM3%2@ERPM).
On 24-FEB-2000 moveing a fleky cable we solved the problem because starting
from RUN 19153 the number of fake decreased.
Since RUN 19154 we didn't recive any more fake.
Ciao, Roberto.