Kinetic power supply model 1502 (SM3 crate 7) Broken


Subject: Kinetic power supply model 1502 (SM3 crate 7) Broken
Roberto.Giuliani@lngs.infn.it
Date: Mon Nov 06 2000 - 07:10:07 EST


  Hi all,
The kinetic (Model 1502) power supply on SM3 crate 7 broken on saturday
during run 20092.
This morning we started run 20096 after the kinetic replacement.
Notice that we used the last good spare supply for model 1502.

Anyway until run 20098 it was impossible to collect good data because PHRASE had
problem with sync. on SM4.

We solved the PHRASE problem swapping a channel on SM4 PHRASE fan-out, at last
run 20098 is running properly with all uVAX in acquisition.
 
Ciao, Roberto.



This archive was generated by hypermail 2a24 : Mon Nov 06 2000 - 07:10:13 EST