PMT HV files


Subject: PMT HV files
SCINTSOFT@lngs.infn.it
Date: Mon Nov 15 1999 - 05:05:50 EST


Hi all--
Ioannis and myself updated and cross checked PMT logbook and HV files
for SM1/2/5/6. The PMTHV.DAT file is updated and EMILY is reactivated.
There should be no HV errors reported. With what concerns tank ends in
SM1/2 that need individual work, here's the list:

  1B12-0 # 59 = 0 ! -00 OK at 1485 -01 no signal
  1C12-0 # 91 = 0 ! -00 ok at 1785 -01 OK at 1480
  1W05-0 #116 = -1505 ! to check for light leak
  1W05-1 #124 = -1710 ! to check for light leak
  1T04-0 #179 = -1540 ! to be opened
  2B15-0 # 62 = -1485 ! to be opened
  2B11-1 # 74 = -1600 ! to be opened
  2C11-0 # 90 = -1555 ! to be opened
  2C14-0 # 93 = -1590 ! check separately
  2W11-0 #147 = -1520 ! check for light leaks
  2E04-1 #139 = -1235 ! noisy fanout
  2E11-1 #171 = -1572 ! noisy fanout
  2T06-0 #181 = -1600 ! to be opened
  2T07-0 #182 = -1480 ! 12-NOV-99; tube flashed - later stabilized

--Erik