Diagnosis of NGC003 processing


Subject: Diagnosis of NGC003 processing
Nicola.Zaccheo@lngs.infn.it
Date: Tue Jun 27 2000 - 12:01:40 EDT


Nicola Zaccheo, 27-JUN-2000

This is the report of NGC003 processing.

From: AXPGS3::MACROUSA "LNGS US MACRO group" 26-JUN-2000 12:38:40.61
Subj: Start COPY of FIRST (#1) file of NGC003 (RUN011321) Selected CPU:0/DISK:9
From: AXPGS3::MACROUSA "LNGS US MACRO group" 26-JUN-2000 15:17:05.15
Subj: Done COPY of LAST (#253) file of NGC003 (RUN090112) Selected CPU:0/DISK:9

Download from tape to disk lasted ~ 2.8 hrs.

From: VAXGS::MACROUSA "LNGS US MACRO group" 26-JUN-2000 15:17:09.66
Subj: Submitted FIRST (#1) NGC MONITOR job of NGC003 (RUN011321) Selected CPU:0/DISK:9
From: VAXGS::MACROUSA "LNGS US MACRO group" 27-JUN-2000 14:40:01.38
Subj: Submitted LAST (#253) NGC MONITOR job of NGC003 (RUN090112) Selected CPU:0/DISK:9

The processing of the GC DSTs files lasted ~ 23.4 hrs. I have now inserted
the GC DSTs g-zipping.

We received following warnings:

        SIZE RUN81247 NGC003 GC ACT 3884 TC ACT -1-mu=3613-NO - Problematic run TC LOG ERRORS RUN81247 NGC003 SIZE= 0-OK
        CLGC:NGC003 RUN081247 CAL fail:1,done:4,exp:5 PROBLEM
this was a LED/FMT 'special' run. It had GUT15_WFD.LIS as Camac list
on uVax1, GUT15.LIS2 and GUT18_CAL_CHUCK.LIS on the other uVaxes.

        SIZE RUN81255 NGC003 GC ACT 4479 TC ACT -1-mu=3015-NO - Problematic run TC LOG ERRORS RUN81255 NGC003 SIZE= 0-OK
        CLGC:NGC003 RUN081255 CAL fail:1,done:4,exp:5 PROBLEM
this was a LED/FMT run (strange comment: 2 FMT calib. in the same run (P.S.))

        SIZE RUN90096 NGC003 GC ACT 6194 TC ACT -1-mu=2867-NO - Problematic run TC LOG ERRORS RUN90096 NGC003 SIZE= 0-OK
        CLGC:NGC003 RUN090096 CAL fail:1,done:4,exp:5 PROBLEM
This was a bad laser lower calibration.

        SIZE RUN90097 NGC003 GC ACT 5021 TC ACT -1-mu=2789-NO - Problematic run TC LOG ERRORS RUN90097 NGC003 SIZE= 0-OK
        CLGC:NGC003 RUN090097 CAL fail:1,done:4,exp:5 PROBLEM
This was a bad laser lower calibration. It is flagged as 'Normal run'

        CLGC:NGC003 RUN011559 CAL fail:0,done:4,exp:5 PROBLEM
For the run above, the TC job crashed with 'ZEBRA post-mortem' before launching
the checker. I launched the 'SAFE' version that crashed again with same error.
This was a run with a very high ERP trigger rate on SM6.

        SIZE RUN90107 NGC003 GC ACT 6335 TC ACT -1-mu=2960-NO - Problematic run TC LOG ERRORS RUN90107 NGC003 SIZE= 0-OK
        CLGC:NGC003 RUN090107 CAL fail:1,done:4,exp:5 PROBLEM
This was a bad laser lower calibration.

        SIZE RUN90108 NGC003 GC ACT 5096 TC ACT -1-mu=2779-NO - Problematic run TC LOG ERRORS RUN90108 NGC003 SIZE= 0-OK
        CLGC:NGC003 RUN090108 CAL fail:1,done:4,exp:5 PROBLEM
This was a bad laser attico calibration.

        SIZE RUN11581 NGC003 GC ACT 93996 TK ACT 2772 CL ACT -1-OK TC LOG ERRORS RUN11581 NGC003 SIZE= 3-NO
        LIP2 DST LOG ERRORS RUN11581 NGC003 SIZE= 3-NO
        CLGC:NGC003 RUN011581 CAL fail:2,done:3,exp:5 PROBLEM
For the above run the TC_MON and the L2_mon crashed at the same event. The
processing jumps to the next event. It was a run with a high ERP trigger rate
on SM6.

        SIZE RUN11594 NGC003 GC ACT 397 MA ACT 1-mu=0-NO MA LOG ERRORS RUN11594 NGC003 SIZE= 0-OK
        CLGC:NGC003 RUN011594 CAL fail:1,done:4,exp:5 PROBLEM
This was a bad run (lasted 15 sec.) with 1 ERP-GC and 5 PHRASE triggers only

I manually g-zipped the GC DSTs files for all the above 9 runs in order to
launch the TAPEMAKER for this NGC



This archive was generated by hypermail 2a24 : Tue Jun 27 2000 - 12:01:51 EDT