Subject: RE: Calibration runs 90103, 90104, 90107 and 90108
Nicola.Zaccheo@lngs.infn.it
Date: Wed Sep 06 2000 - 04:54:42 EDT
From: VAXGS::ZACCHEO 6-SEP-2000 10:49:15.07
To: SMTP%"Ioanni.Katsavounidis@lngs.infn.it"
CC: KATSVNDS,ZACCHEO
Subj: RE: Calibration runs 90103, 90104, 90107 and 90108
Ciao Yiannis,
in fact the VAX time on VSMAC1 was wrong at that time.
This is the right situation:
run 90103 LED/TDC (not SMT) started: 10JAN96 at 10:45
" 90104 FMT " " " " at 11:05
" 90107 LASER low. " " " " at 11:40
" 90108 LASER att. " " " " at 12:00
There are ~ 15.5 hrs of difference between the LGB time and
the real acquisition time.
I found the same problems for the following week (17JAN96) and
no problems starting from run 90113 (24JAN96).
Unfortunately I didn't find any comments on the paper logbook.
Note that the two previous weeks (03JAN96 and 27DEC95) the
calibrations were performed using VSMACR while three weeks
before (20DEC95) were performed using VSMAC1 w/o problems.
I hope that my previous e-mail regarding the NOV95 gain setting
has been useful for your work. Anyway I'm at your disposal for
any other questions.
A presto,
Nicola
This archive was generated by hypermail 2a24 : Wed Sep 06 2000 - 04:54:50 EDT