ERP TPU for 1C13-1C16 fixed


Subject: ERP TPU for 1C13-1C16 fixed
From: Alec Habig (habig@budoe.bu.edu)
Date: Fri Nov 12 1999 - 10:59:55 EST


Hi all,

The TPU for erp channels 1C12-1C16 was a casulty of the power outage on
Wed. It has been dead from the first run after power restoration,
18563, to run 18574 (the last run before uVAX1 went out for
gainsetting). No dead components were found on the autopsy, so this
board gets to return home to IU on medical leave.

A new TPU has been swapped in, and these channels are working again now.

  Alec

-- 
       Alec Habig, Boston University Particle Astrophysics Group
			   habig@budoe.bu.edu
		       http://hep.bu.edu/~habig/



This archive was generated by hypermail 2a24 : Fri Nov 12 1999 - 10:59:56 EST