Subject: 6S05 back in acquisition
Nicola.Zaccheo@lngs.infn.it
Date: Thu Dec 16 1999 - 06:24:32 EST
Ciao a tutti,
starting from run 18759 6S05 is back in acquisition.
The related LeCroy HV channel (#219) was broken because it gave
a higher HV value than the one demanded. In fact I found this
box in big overgain and I didn't see any gain variation lowering
the HV value. I swapped 6S05-1 (LeCroy ch.219) on 6SPD-F (LeCroy ch.222)
and I have already updated the PMTHV.dat file.
A presto,
Nicola